This document contains information on new features,
corrections of known issues, limitations and new peripheral solutions.
Table of Contents
There are no new features for this release.
Files
- The "all files *.*" option is no longer
accessible from the Open/Files dialog box
- Label created with CS 5, opened with CS7
would cause the database key field in the Table lookup to skip from line 1 to
line 2
Printers
- The Windows printer settings are saved with
the label
Printing
- When doing an ASCII merge with a laser printer
AND with no more than one label on a page, confirmation is asked for each
record of database file
- Reset to value is now correctly set when
printing from the form display mode
- Counter now keeps the value while printing.
It asks to save after label reopening ans some printing counter increment
- Date from logfile settings is now added in the
print logfile
- A SERIALQTY variable can be used for the print
quantity even if another number has been given with the printable command.
- TEC lines using a TTF (True Type Font) with a
rotation of 90 or 270 degrees are no longer being truncated on printout.
- a printjob of more than 9999 label will only
print 9999 labels. A last label will be printed with the remnant of the
integer division by 9999.
Variable
- The "Display in form" option is now saved with
the lab file
- Date variables used in formula are now updated
when opening a label through File > Open menu (double clicking on lab also
works)
- @PRINTERNAME variable value returns the old
value if the printer is changed just before a printjob
- Decimal counters with an alphabetical value
will be printed.
- If creating a shared form variable and putting
a Unicode value inside, a result value is now provided after validation and
editing.
- Datbase field can now have more than 1024
characters.
Graphics
- The information in the Preview is correctly
displayed.
- It is possible to give path instructions in a
variable value for an image, to complete the default path. However, to have
the possibility to have a part of the path in the variable value you must :
- type: "part2\img" to have "c:\part1\part2\img.bmp"
if you set the default folder or the other folder at "c:\part1" and the
default extension at ".bmp".
- OR, You can also use ".\" or "..\" to solve the location,
the start path is the default folder or the other folder name.
Caution ! :
You must type "\\" only for the UNC and ":\" only for the map drive.
ODBC/OLEDB
- A query can be saved when saving a label, even
if the query has not been modified
- Table Lookup variables: if the ODBC datasource
does not exist, CODESOFT returns an error message
Text Object
- Object name no longer changes when using the
UNDO function.
Settings
- It is possible to change the assigned
shortcuts for User Tools from the Shortcut Keys dialog box
ActiveX
- PrintLabel and Merge methods: the LABELNOFROM
parameter is working
- A merge with an ASCII database is no longer
printing only on the first label
- DateOffsetValue and OffSetUnit are now
functional
Network Connection
- When running CODESOFT, if one of the default
Network share directories does not exist, (Network connection is not found), a
warning will be prompted and the user will be directly redirected to the
Tools\Options\Default folder dialog box to solve it.
Other
- Re-ordered information in a label in the form
display mode will keep its position after saving and reopening the label at a
later date
- The ASCII file descriptor is no longer limited
to 20 fields
- There is no longer any confusion regarding CS
driver names and MS Windows names
- 'Copy to clipboard' now works correctly
None to be reported at this time
The following list of printers and their
associated drivers have been included in the printer selection list of
available printers.
Avery
- Avery 64-05 (RFID)
- Avery AP 7.t(200dpi)
- Avery AP 7.t(300dpi)
BP Precision
- BP Precision 200
- BP Precision 300
- BP Precision 600
Brady
- Brady Tagus T200
- Brady Tagus
T300
Citizen
Datamax
- Datamax I-4210 RFID HF
- Datamax
I-4210 RFID UHF
- Datamax I-4212 RFID HF
- Datamax I-4212 RFID UHF
- Datamax
I-4308 RFID HF
- Datamax I-4308 RFID UHF
- Datamax I-4406 RFID HF
- Datamax
I-4406 RFID UHF
- Datamax I-4604 RFID HF
- Datamax I-4604 RFID UHF
Imaje
- Imaje 242x (200dpi)
- Imaje 243x
(305dpi)
- Imaje 262x (200dpi)
- Imaje 263x (305dpi)
- Imaje MP
Compact4 (203dpi)
- Imaje MP Compact4 (300dpi)
- Imaje MP Compact4 Mobile
(203dpi)
- Imaje MP Compact4 Mobile (300dpi)
- Imaje MP Nova4 (203dpi)
- Imaje
MP Nova4 (300dpi)
- Imaje MP Nova4 TT (203dpi)
- Imaje MP Nova4 TT (300dpi)
- Imaje MP Nova6 (203dpi)
- Imaje MP Nova6 (300dpi)
- Imaje MP Nova6 TT (203dpi)
- Imaje MP Nova6 TT (300dpi)
- Imaje MP Nova8 (203dpi)
- Imaje 2300
Intermec
- EasyCoder PC4 (203dpi)
- EasyCoder PC4 (300dpi)
- EasyCoder PX6i IPL mode (300dpi)
- EasyCoder PX4i IPL
mode (300dpi)
- EasyCoder PF4i IPL mode (300dpi)
- EasyCoder PM4i IPL mode
(300dpi)
Markem
- Markem CimJet 300 104mm/8 dot
- Markem CimJet 300 152mm/8 dot
- Markem CimJet 300 107mm/12 dot
- Markem CimJet
200 104mm/8 dot
Printronix
- Printronix T5204 RFID (PGL)
- Printronix T5304 RFID (PGL)
Ricoh
- Ricoh IP6500
- Ricoh IP6500C
Sato
- Sato MB 200
- Sato MB 400
- Sato
GT408e
- Sato GT412e
- Sato GT424e
- Sato CL 408e HF
- Sato CL 412e HF
- Sato CL 408e UHF
- Sato CL 412e UHF
- Sato M 8485SE UHF
- Sato CT 420
Tec
Tharo
- Tharo H-434
- Tharo H-426
- Tharo
V-426
- Tharo V-433
Zebra
- Zebra R110Xi (203dpi)
- Zebra R110Xi (300dpi)
- Zebra R170Xi (203dpi)
- Zebra R170Xi (300dpi)
- Zebra LP
2824-Z
- Zebra TLP 2824-Z
- Zebra TLP-2824-Z
- Zebra LP-2824-Z
- Zebra R110XiIII Plus (203dpi)
back